HyQual - Multi-Parameter Water Quality Probes
KISTERS multi-parameter water quality probes HyQual 200, HyQual 300 and HyQual 300T are your individual complete solutions in water quality analysis. Depending on the chosen model and optional extensions, the sensors can determine a subset or all of the… Read more
HyQual 200 |
HyQual 300 |
HyQual 300T |
|
Diameter | 50 mm (1.95”) | 75 mm (2.95”) | 75 mm (2.95”) |
Length | 47.8 cm (18.8”) | 47.8 cm (18.8”) | 47.8 cm (18.8”) |
Mass | 0.82 kg (1.8 lbs) | 1.63 kg (3.6 lbs) | 1.63 kg (3.6 lbs) |
Standard | Temperature sensor, dissolved oxygen sensor, specific conductivity sensor, pH sensor, ORP sensor, calculated total dissolved solids, calculated salinity, interface RS-232, weighted sensor guard, internal memory (months of data logging), maintenance kit, carrying case, non-vented underwater cable (5, 10, 20, 30, 40 and 50 m) | ||
Standard | Turbidity sensor, wiper (HyQual 300T) | ||
Options | Depth (level) sensor, barometric pressure, vented capacity, data cable for display devices (not for field use), Bluetooth® wireless technology lithium battery pack, calibration solutions, copper anti-fouling kit, USB adapter (connect DB9 to USB), integrated SDI-12 and MODBUS output, SDI-12 adapter cable, MODBUS adapter cable, Android™ display | ||
Options | External rechargeable battery for unattended registration/stand-alone capacity (HyQual 300 / 300T) | ||
Material | Resistant materials like stainless steel 303 and 316, polyacetal (Delrin), PVC, Teflon, ABS, titanium, Viton, neoprene, silicone, glass | ||
Power Supply and Consumption |
|
||
Output Options (Interfaces) | Standard: RS-232 or Optional: Bluetooth® wireless technology, SDI-12 and MODBUS | ||
Certifications | CE, RoHS (WEEE pending) |
Technical Specifications (Parameters)
Parameter (units) |
Range |
Resolution |
Accuracy |
Temperature (°C) | -5 to 50 | 0.01 | 0.1 |
pH | 0 to 14 | 0.01 | 0.1 |
ORP (mV) | -999 to 999 | 1 | 20 |
Specific Conductivity (uS/cm) |
0 to 200000 | four digits; maximum of one decimal |
1 % of reading +/-1 |
Dissolved Oxygen (% Sat) | 0 to 200 200 to 500 |
0.1 % - |
0.2 % 2 % |
Dissolved Oxygen (mg/l) | 0 to 50 | 0.1 mg/l | 2 mg/l |
Turbidity (FNU, NTU) | 0 to 1000 1000 to 4000 |
four digits; maximum of two decimal |
0.3 or 2 % of reading 4 % of reading |
Depth (m) | 0 to 25 | 0.01 | 0.05 |
Barometric Pressure (mbar) | 400 to 900 | 0.1 | 1.5 |
Total Dissolved Solids (g/l) | 0 to 65 | 0.01 | 5 % of reading |
Salinity (PSS) | 0 to 70 | 0.01 | 0.1 |
KISTERS multi-parameter water quality probes HyQual 200, HyQual 300 and HyQual 300T are your individual complete solutions in water quality analysis. Depending on the chosen model and optional extensions, the sensors can determine a subset or all of the following parameters:
- Temperature
- Optical dissolved oxygen
- Specific conductivity
- pH
- ORP
- Turbidity
- Total dissolved solids (calculated)
- Salinity (calculated)
- Depth (level) up to 50 m
- Barometric pressure
HyQual stands out for its rugged and compact design and is made from durable materials such as 303 and 316 stainless steel, polyacetal (delrin), PVC, teflon, ABS, titanium, viton, neoprene, silicone, and glass, for deployment even in harsh environments as waste water or industrial water. The probes are simple to calibrate, implement, and use. They provide reliable, stable, and repeatable results.
HyQual probes are known for their exceptional quality. This is why they come with a free extended warranty of 3 years world-wide.
Easy connectivity and deployment
- For spot measurements, HyQual can be connected to almost any smartphone, tablet or other display device (Android™) via a Bluetooth® wireless technology transceiver. The probe communicates and is powered via its underwater cable connected to the rechargeable transceiver housed in a waterproof (IP67) case.
- For continuous logging, HyQual probes can be connected via an underwater cable RS-232 /SDI-12 to an external data logger/power supply.
- For both continuous logging or spot measurement, HyQual has an optional rechargeable external battery pack for a self-contained data logger.
All HyQual versions are enclosed in a waterproof (IP67) case and can be optionally equipped with an SDI-12 or MODBUS interface.
HyQual probes come with an easy-to-use app for accessing functions and data. It offers the usual functions (such as calibrations, parameter selection, snapshot data capture, etc.) plus geofencing, automatic logging, and emailing of data.
- Rugged and compact design
- Low maintenance
- Easy to install and use
- Several output options like RS-232 (standard) or Bluetooth® wireless technology, SDI-12 and MODBUS (optional)
- CE-certified
- Compatible with KISTERS range of data loggers
HyQual is suitable for manual spot checking as well as unattended logging in
- Wastewater, groundwater, industrial water, brackish water, seawater
- Lakes, rivers, estuaries
- Boreholes
- Education, research and laboratories
- Aquaculture
-
HyQual brochure
-
HyQual User Manual
-
HyQual app - User manual
-
FAQs Frequently Asked Questions - HyQual
-